    3. what is EN/IEC 60068-2-75 IK hammer test and striking elements?

      2025-08-01

      WHAT IS STANDARD EN/IEC 60068-2-75?

      HAMMER TEST

      Standard EN/IEC 60068 consists of 3 methods for testing the impact resistance of a test object against impacts with different severity levels. It serves to demonstrate the mechanical strength of a product and is intended primarily for the testing of electrical equipment. The test consists of a standardised test procedure with a defined number of impacts on the test object with a defined impact energy. Standard IEC 60068-2-75 covers impact energies from 0.14 J to 50 J.

      EN 60068-2-75 DIMENSIONS TABLE OF IMPACT ELEMENTS

      IK CODE

      IK00

      IK01

      IK02

      IK03

      IK04

      IK05

      IK06

      IK07

      IK08

      IK09

      IK10

      IK11

      Impact energy (Joule)

      *

      0.14

      0.20

      0.35

      0.50

      0.70

      1.00

      2.00

      5.00

      10.00

      20.00

      50.00

      Drop Heigth (mm)

      *

      56

      80

      140

      200

      280

      400

      400

      300

      200

      400

      500

      Mass (kg)

      *

      0.25

      0.25

      0.25

      0.25

      0.25

      0.25

      0.50

      1.70

      5.00

      5.00

      10.00

      Material

      *

      P1

      P1

      P1

      P1

      P1

      P1

      S2

      S2

      S2

      S2

      S2

      R (mm)

      *

      10

      10

      10

      10

      10

      10

      25

      25

      50

      50

      50

      D (mm)

      *

      18.5

      18.5

      18.5

      18.5

      18.5

      18.5

      35

      60

      80

      100

      125

      f (mm)

      *

      6.2

      6.2

      6.2

      6.2

      6.2

      6.2

      7

      10

      20

      20

      25

      r (mm)

      *

      6

      10

      17

      l (mm)

      *

      Must be adapted to the appropriate mass

      Swing hammer

      *

      Yes

      Yes

      Yes

      Yes

      Yes

      Yes

      Yes

      Yes

      Yes

      Yes

      Yes

      Spring hammer

      *

      Yes

      Yes

      Yes

      Yes

      Yes

      Yes

      No

      No

      No

      No

      No

      Free fall hammer

      *

      No

      No

      Yes

      Yes

      Yes

      Yes

      Yes

      Yes

      Yes

      Yes

      Yes

      Specifications from the standard EN 60068-2-75

      * not protected according to the standard

      1.Polyamide 85 ≤ HRR ≤100 Rockwell hardness according to ISO 2039/2

      2.Steel Fe 490-2 according to ISO 1052, Rockwell hardness HRE 80...85 according to ISO 6508

      1.png

      Table 1 Striking element characteristics

      Energy / J

      ≤1

      ±10%

      2

      ±5%

      5

      ±5%

      10

      ±5%

      20

      ±5%

      50

      ±5%

      Equivalent Mass ±2%kg

      0.25(0.2)

      0.5

      1.7

      5

      5

      10

      Material

      Nylon

      Steel

      R/mm

      10

      25

      25

      50

      50

      50

      D/mm

      18.5(20)

      35

      60

      80

      100

      125

      f/mm

      6.2(10)

      7

      10

      20

      20

      25

      r/mm

      -

      -

      6

      -

      10

      17

      l/mm

      Adjusted according to the equivalent mass, see Appendix A


      Table 2 Height of Fall

      Energy /J

      0.14

      0.2

      (0.3)

      0.35

      (0.4)

      0.5

      0.7

      1

      2

      5

      10

      20

      50

      Equivalent Mass /kg

      0.25

      (0.2)

      0.25

      (0.2)

      0.25

      (0.2)

      (0.2)

      0.25

      0.25

      0.25

      0.5

      1.7

      5

      5

      10